beautypg.com

KACO Powador XP500-XP550-HV TL outdoor User Manual

Page 44

background image

Operating Instructions Powador XP500/550-OD-TL

Page 45

F a u l t s a n d W a r n i n g s

Message

Code

Description

Grid Over Frequency 1

32

Grid side Frequency over the parameter [Grid Over Frequency Level 1]

Grid Under Frequency 1

33

Grid side Frequency under the parameter [Grid Under Frequency Level 1]

Grid CB Trip

34

CB20(AC Disconnect/Grid circuit breaker) was tripped during operation

Grid Over Voltage 2

35

Grid side Voltage over the parameter [Grid Over Voltage Level 2]

Grid Under Voltage 2

36

Grid side Voltage Under the parameter [Grid Under Voltage Level 2]

Grid Under Frequency 2

37

Grid side Frequency Under the parameter [Grid Under Frequency Level 2]

Grid Over Frequency 2

38

Grid side Frequency Over the parameter [Grid Over Frequency Level 2]

Parameters Version Error

40

Different version between the NVSRAM parameter table and the pro-
gram parameter table

Flash Memory Failure

41

C6000 DSP program fl ash memory failure in XCU(main control) board

FPGA Failure

42

FPGA failure in XCU(main control) board

DSP28x Failure

43

F2000 DSP failure in XCU(main control) board

ADC Failure

44

ADC block failure in XCU(main control) board

NVSRAM Failure

45

NVSRAM Failure in XCU(main control) board or invalid parameter set-
ting

Asynchronous

46

Synchronous fail of Grid and Inverter

CAN Failure

47

CAN bus communication failure

Emergency Stop

50

A door is open

MasterSlave Fault

52

Master Slave operation Failure

Grid Over Frequency Level3 57

Grid side Frequency over the parameter [Grid Over Frequency Level 3]

Grid Under Frequency
Level3

58

Grid side Frequency under the parameter [Grid Under Frequency Level 3]

Grid Over Voltage Slow

59

Grid side Voltage over the parameter [Grid Over Voltage Level Slow]
(RMS average value per 10 min)

MMI-XCU Communication
Error

63

MMI-XCU communication Error

Table 8: Fault