F a u l t s a n d W a r n i n g s

Code

Message

Warning Description

Possible problem and Solution(s)

10

Inv. Over Voltage

Inverter side Voltage over the
parameter [Grid Over Voltage
Level 2]

Possible problem

• The inverter voltage is too high
Solution(s)

• Check the inverter voltage

• Check the inverter parameter

11

Inv. Under Voltage

Inverter side Voltage under the
parameter [Grid Under Voltage
Level 2]

Possible problem

• The inverter voltage is too low
Solution(s)

• Check the inverter voltage

• Check the inverter parameter

• Check the MC21

12

Inv. Over Frequency

Inverter side Frequency over the
parameter [Grid over Frequency
Level 2]

Possible problem

• The grid frequency is outside the
permitted range
Solution(s)

• Check the grid frequency

13

Inv. Under Frequency Inverter side Frequency under

the parameter [Grid under
Frequency Level 2]

Possible problem

• The grid frequency is outside the
permitted range
Solution(s)

• Check the grid frequency

14

Inv. Over Current

Inverter side Current over the
parameter [Inverter OverCurrent
Level]

Possible problem

• Short circuit in the IGBT

• Short circuit in the Grid
Solution(s)

• Check the grid connection

• Check the inverter connection

15

MC21(Inv. MC) Failure Inverter side contactor(MC21)

failure

Possible problem

• MC21 contactor is open

• Auxiliary switch is inoperable
Solution(s)

• Check the wiring connection

• Change the MC21

16

Inv. Phase Order

Phase order failure on the
inverter side

Possible problem

• Phase order failure on the inverter

• Wrong phase rotation
Solution(s)

• Check the wiring connection

• Reverse two phases

Table 10: Fault