beautypg.com

8 software upgrade – KACO Powador XP500-XP550-HV TL outdoor User Manual

Page 34

background image

Operating Instructions Powador XP500/550-OD-TL

Page 35

S t o r a g e / I n s t a l l a t i o n / S t a r t - u p

5.8 Software

upgrade

5.8.1 Changing the SD card, HMI status

Buzzer tells you the status of the SD card because HMI has no LCD Display.

beep once as short

Complete the network setting after SD card recognition

beep twice as long

Start upgrade HMI Software

beep three times as long

Start upgrade XCU Software

beep three times as short

Successfully upgraded

beep eight times as short

Upgrade fails

Table 6: Changing the SD card, HMI status

*When HMI is not beep (once as short) after inserting the SD card, please reinsert SD card into the HMI after a
few seconds.

DANGER

Lethal voltages are still present in the terminals and lines of the inverter even after
the inverter has been switched off and disconnected!

Coming into contact with the lines and terminals in the inverter will cause serious
injury or death.

Only authorised electricians who are approved by the supply grid operator may open,
install and maintain the inverter.

Keep all doors and covers closed when the unit is in operation.

Do not touch the lines and terminals when switching the unit on and off!