beautypg.com

3 s0 output, 4 digital output – KACO Powador XP500-XP550-HV TL outdoor User Manual

Page 92

background image

Operating Instructions Powador XP500/550-OD-TL

Page 93

U s e r i n t e r f a c e

9.1.3 S0

output

24Vdc

1c

1c

1d

1d

2c

2c

2d

2d

UDIO

0Vdc

4.7 kΩ

Output signal

3c

3c

3d

3d

4c

4c

4d

4d

5c

5c

5d

5d

Figure 69: Connection for S0 output

Terminal number

Terminal designation

Specifi cation

Wire cross- section

3c

S0

out

P

Max 27Vdc, 27mA

AWG 20

(0.518mm

2

)

3d

S0

out

N

Table 23: Connections for S0 output

9.1.4 Digital

output

1c

1c

1d

1d

2c

2c

2d

2d

UDIO

3c

3c

3d

3d

4c

4c

4d

5c

5c

5d

1c

1c

1d

1d

2c

2c

2d

2d

UDIO

3c

3c

3d

3d

4c

4c

4d

5c

5c

5d

Figure 70: Connection for digital output

(N/O contact)

Figure 71: Connection for digital output

(N/C contact)

Terminal number Terminal designation

Specifi cation

Wire cross-section

4c

UDO1A

Potential-free output

contact A

AWG 20

(0.518mm

2

)

4d

UDO1B

Potential-free output

contact B

5c

UDIO1C

Potential-free, common

output contact

5d

UDIO1D

-

Table 24: Connections for digital user output