4 details on i/o error status – Yaskawa JAPMC-MC2303-E User Manual
Page 147
7
T
roubleshooting
7.2 Common Network Problems and Countermeasures
7.2.4 Details on I/O Error Status
7-9
7.2.4 Details on I/O Error Status
When a system I/O error occurs, the error status will be written in the system register.
The registers allocated for each error status when an I/O Module (LIO-01/02), FL-net Communication Module (262IF-
01), and DeviceNet Communication Module (260IF-01) are mounted in slots 1, 2, and 3 of the MP2300 Machine Con-
troller respectively are described below.
[ a ] MP2300 Machine Controller Basic Module Error Status
Register Allocation: Slot 0 (Reserved for Basic Module)
Name
Register No.
Remarks
Slot 0 Error Status
SW00208 to
SW00215
(Depends on the mounted module and error code.)
Reserved by the system
SW00216 to
SW00223
(Depends on the mounted module and error code.)
Slot 1 Error Status
SW00224 to
SW00231
(Depends on the mounted module and error code.)
Slot 2 Error Status
SW00232 to
SW00239
(Depends on the mounted module and error code.)
Slot 3 Error Status
SW00240 to
SW00247
(Depends on the mounted module and error code.)
ST#15
SW00210
Error code (I/O error = 2)
Subslot No. (= 2)
SW00208
Error code (Station error = 1)
Subslot No. (= 3)
SW00209
(Bit No.)
F ̖̖̖̖̖̖̖̖̖̖̖̖̖̖87 ̖̖̖̖̖̖̖̖̖̖̖̖̖̖0
̖̖̖̖
̖̖̖̖
̖̖̖̖
̖̖̖̖
̖̖̖̖
̖̖̖̖
ST#2
ST#1
Not used
Not used
SW00211
ST#30
ST#17
ST#16
Not used
SW00212
Not used
Not used
SW00213
Not used
Not used
SW00214
Not used
Not used
SW00215
Not used