9.5 Analog Monitor

9-29

9

(1) Manual Zero Adjustment of Analog Monitor Output (Fn00C)

Follow the procedure below to execute the manual zero adjustment of analog monitor output.

Step Display after Operation

Key

Description

1

Press the DSPL/SET Key to select the utility function mode.

2

Press the LEFT/RIGHT Key or the UP/DOWN Key to set the
parameter Fn00C.

3

Press the DATA/ENTER Key, and “Ch1_o” will be displayed.

4

Press the DSPL/SET Key, and the monitor output for the two
channels will be displayed alternately.

5

Press the LEFT or RIGHT Key to display the analog monitor out-
put data. Pressing the LEFT or RIGHT Key again will return to
“Ch1_o” or “Ch2_o”.

6

Press the UP or DOWN Key to perform zero adjustment confirm-
ing the output waveform of the analog monitor with the measur-
ing device.

7

Press the DATA/ENTER Key to return to the utility function
mode display Fn00C.

DSPL

SET

(DSPL/SET Key)

DATA

ENTER

(DATA/ENTER Key)

Displayed
alternately

DSPL

SET

(DSPL/SET Key)

Displayed
alternately

DATA

ENTER

(DATA/ENTER Key)