6 Wiring

6.1.1 Names and Functions of Main Circuit Terminals

6-2

6.1 Wiring Main Circuit

This section describes typical examples of main circuit wiring, functions of main circuit terminals, and the power
ON sequence.

6.1.1 Names and Functions of Main Circuit Terminals

• Do not bundle or run power and signal lines together in the same duct. Keep power and signal lines sepa-

rated by at least 300 mm (11.81 in).
Failure to observe this caution may result in malfunction.

• Use twisted-pair shielded wires or multi-core twisted pair shielded wires for signal and encoder (PG) feed-

back lines.
The maximum length is 3 m (118.11 in) for reference input lines and is 20 m (787.40 in) for PG feedback lines.

• Do not touch the power terminals for five minutes after turning power OFF.

Make sure the charge indicator is turned OFF first before starting an inspection.

• Avoid frequently turning power ON and OFF. Do not turn the power ON or OFF more than once per minute.

Since the SERVOPACK has a capacitor in the power supply, a high charging current flows for 0.2 seconds when the
power is turned ON. Frequently turning the power ON and OFF causes main power devices such as capacitors and
fuses to deteriorate, resulting in unexpected problems.

Terminal Symbol

Name

Main

Circuit

Voltage

(V)

Maximum

Applicable

Servomotor

Capacity

(kW)

Functions

L1,L2

Main circuit power
supply input terminal

24

0.05 to 0.08

24 VDC (

±15%)

48

0.05 to 0.3

48 VDC (

±15%)

U,V,W

Servomotor
connection terminals

Connects to the servomotor.

C1, C2

Control circuit power
supply input terminal

24

0.05 to 0.08

24 VDC (

±15%)

48

0.05 to 0.3

48 VDC (

±15%)

Ground terminals

Connects to the power supply ground terminals and
servomotor ground terminal.

CAUTION