3 installation conditions of emc directives, 1) emc installation conditions – Yaskawa Sigma II Series DC Power Input SGMAJ User Manual
Page 140

6.4 Others
6-21
6
6.4.3 Installation Conditions of EMC Directives
To adapt a combination of a SGMAJ servomotor and a SGDJ SERVOPACK to EMC Directives (EN55011
group1 classA, EN61000-6-2), the following conditions must be satisfied.
(1) EMC Installation Conditions
This section describes the installation conditions that satisfy EMC guidelines for each model of the SGDJ
SERVOPACK.
This section describes the EMC installation conditions satisfied in test conditions prepared by Yaskawa. The
actual EMC level may differ depending on the actual system’s configuration, wiring, and other conditions.
CN4
CN1
1
2
3
4
5
U, V, W
24V/48V
GND
SERVOPACK
SGDJ-
FG
Servo-
motor
Encoder
Ground Plate / Shield Box
Clamp
Core
Core
Core
Core
Clamp
Host controller
Clamp
Approx. 2 m (6.56 ft)
Approx. 20 m (65.6 ft)
Power Supply
Single-phase
100 VAC or 200 VAC
Noise
filter
Power Supply
AC/DC
Output:
24 V/48 V
Symbol
Cable Name
Specifications
c
Controller cable
Shield cable
d
Motor cable
Shield cable
e
Encoder cable
Shield cable
f
AC Line cable
Unshield cable
g
DC Line cable
Unshield cable
- Tag Generator (30 pages)
- MP3300iec (82 pages)
- 1000 Hz High Frequency (18 pages)
- 1000 Series (7 pages)
- PS-A10LB (39 pages)
- iQpump Micro User Manual (300 pages)
- 1000 Series Drive Option - Digital Input (30 pages)
- 1000 Series Drive Option - CANopen (39 pages)
- 1000 Series Drive Option - Analog Monitor (27 pages)
- 1000 Series Drive Option - CANopen Technical Manual (37 pages)
- 1000 Series Drive Option - CC-Link (38 pages)
- 1000 Series Drive Option - CC-Link Technical Manual (36 pages)
- 1000 Series Drive Option - DeviceNet (37 pages)
- 1000 Series Drive Option - DeviceNet Technical Manual (81 pages)
- 1000 Series Drive Option - MECHATROLINK-II (32 pages)
- 1000 Series Drive Option - Digital Output (31 pages)
- 1000 Series Drive Option - MECHATROLINK-II Technical Manual (41 pages)
- 1000 Series Drive Option - Profibus-DP (35 pages)
- AC Drive 1000-Series Option PG-RT3 Motor (36 pages)
- Z1000U HVAC MATRIX Drive Quick Start (378 pages)
- 1000 Series Operator Mounting Kit NEMA Type 4X (20 pages)
- 1000 Series Drive Option - Profibus-DP Technical Manual (44 pages)
- CopyUnitManager (38 pages)
- 1000 Series Option - JVOP-182 Remote LED (58 pages)
- 1000 Series Option - PG-X3 Line Driver (31 pages)
- SI-EN3 Technical Manual (68 pages)
- JVOP-181 (22 pages)
- JVOP-181 USB Copy Unit (2 pages)
- SI-EN3 (54 pages)
- SI-ET3 (49 pages)
- MECHATROLINK-III (35 pages)
- EtherNet/IP (50 pages)
- SI-EM3 (51 pages)
- 1000-Series Option PG-E3 Motor Encoder Feedback (33 pages)
- 1000-Series Option SI-EP3 PROFINET (56 pages)
- PROFINET (62 pages)
- AC Drive 1000-Series Option PG-RT3 Motor (45 pages)
- SI-EP3 PROFINET Technical Manual (53 pages)
- A1000 Drive Option - BACnet MS/TP (48 pages)
- 120 Series I/O Modules (308 pages)
- A1000 12-Pulse (92 pages)
- A1000 Drive Software Technical Manual (16 pages)
- A1000 Quick Start (2 pages)
- JUNMA Series AC SERVOMOTOR (1 page)
- A1000 Option DI-101 120 Vac Digital Input Option (24 pages)