2 sgdj-***p for position control mode, 2 sgdj-p for position control mode – Yaskawa Sigma II Series DC Power Input SGMAJ User Manual
Page 127

6 Wiring
6.3.2 SGDJ-P for Position Control Mode
6-8
6.3.2 SGDJ-P for Position Control Mode
* 1.
: represents twisted-pair wires.
* 2. Connect a backup battery when using an absolute encoder. When connecting a battery to the host
controller, however, do not connect a backup battery.
* 3. Customers must purchase a 24 VDC power supply with double-shielded enclosure.
* 4. Enabled when using the absolute encoder.
Note: The functions allocated to the input signals SI0 to SI6 and the output signals SO1 to SO3 can be
changed by using the parameters. Refer to 7.3.2 Input Circuit Signal Allocation and 7.3.3 Output
Circuit Signal Allocation.
SERVOPACK
19
+5 V
0 V
SEN
SG
BAT +
BAT -
ALO1
ALO2
ALO3
PBO
PCO
/PBO
PAO
/PAO
/PCO
ALM+
ALM-
FG
36
29
1
2
6
5
4
3
28
34
35
(SI0)
(SI1)
(SI2)
(SI3)
(SI4)
(SI5)
(SI6)
24
20
21
22
23
25
30
31
32
+24 V
+24VIN
3.3 k
Ω
/S-ON
/P-CON
P-OT
N-OT
/ALM-RST
/N-CL
13
15
17
16
18
11
/P-CL
12
14
∗3.
PSO
/PSO
26
27
150
Ω
PULS
CLR
/PULS
SIGN
/SIGN
CLR
/CLR
PULS
∗1.
150
Ω
150
Ω
∗4.
Servo ON
(Servo ON when ON)
Reverse run prohibited
(Prohibited when OFF)
Forward run prohibited
(Prohibited when OFF)
Alarm reset
(Reset when ON)
Reverse current limit
(Limit when ON)
Forward current limit
(Limit when ON)
SEN signal input
Backup battery
2.8 to 4.5 V
∗2.
∗2.
P control
(P control when ON)
SIGN
Position
reference
CW
Phase A
CCW
Phase B
Connect shield
to connector shell.
Connector
shell
Alarm code output
Max. operating voltage:
30 VDC
Max. operating current:
20 mA DC
PG dividing ratio output
Applicable line receiver
SN75175 manufactured
by Texas Instruments or
the equivalent corresponding
to MC3486
Servo alarm output
(OFF for an alarm)
Photocoupler output
Max. operating voltage:
30 VDC
Max. operating current:
50 mA DC
Amount of phase-S rotation
Serial data output
Applicable line receiver
SN75175 manufactured
by Texas Instruments or
the equivalent corresponding
to MC3486
/COIN
/TGON
/S-RDY
(SO1)
(SO2)
(SO3)
Positioning completed
(ON when positioning completes.)
TGON output
(ON at levels above the setting.)
Servo alarm output
(OFF for an alarm)
10
7
9
8
SG-COM