2) sequence i/o signal monitor display, Input signal monitor display – Yaskawa Sigma II Series DC Power Input SGMAJ User Manual
Page 171

7.4 Operation in Monitor Mode (Un)
7-27
7
(2) Sequence I/O Signal Monitor Display
The following section describes the monitor display for sequence I/O signals.
(a)
Input Signal Monitor Display
The status of input signal allocated to each input terminal is displayed:
When the input is in OFF (open) status, the top segment (LED) is lit.
when the input is in ON (short-circuited) status, the bottom segment (LED) is lit.
Refer to 7.3.2 Input Circuit Signal Allocation for the relation between input terminals and signals.
* When using SGDJ-P SERVOPACK for the position control mode, the SEN signal is
assigned Pin No.36.
• When /S-ON signal is ON (Servo ON at L level)
• When /S-ON signal is OFF
• When P-OT signal operates (Operates at H level)
7 6 5 4 3 2 1
Top: OFF (H level)
Bottom: ON (L level)
Number
8
Display LED
Number
Input Terminal Name
Factory Setting
1
CN1-14
/S-ON
2
CN1-15
/P-CON
3
CN1-16
P-OT
4
CN1-17
N-OT
5
CN1-18
/ALM-RST
6
CN1-11
/P-CL
7
CN1-12
/N-CL
8
CN1-5 (36)*
SEN
EXAMPLE
The bottom segment
of number 1 is lit.
7 6 5 4 3 2 1
8
7 6 5 4 3 2 1
8
The top segment of
number 1 is lit.
The top segment of
number 3 is lit.
7 6 5 4 3 2 1
8