beautypg.com

7 mpp limit. val, Mpp limit. val – SMA SC 400HE User Manual

Page 98

background image

9 Parameters

SMA Solar Technology AG

98

SC4-63HE-BE-BEN103280

Operating Manual

9.7 Mpp Limit. Val.

*Only modify parameters after consultation with SMA Solar Technology AG.

Name

Description

Value / range Explanation

Default
value

VmppMin

*

Minimum MPP voltage
required for the Sunny
Central to feed power into
the power distribution
grid.

75 V … 600 V SC 400HE-11

450 V

75 V … 600 V SC 500HE-11

450 V

75 V … 600 V SC 630HE-11

500 V

dVreference

Voltage window for
switching into the
operating mode
"MPP-Search" The
parameter comes into
effect if the value falls
below or exceeds the set
voltage window twice.

5 V … 1 000 V

80 V

5 V … 1 000 V Recommendation for

thin-film PV modules

120 V

PsearchMpp

*

Limiting value for
searching for the MPP
If the value is below the
value "PsearchMpp", the
inverter starts searching
for the MPP again after
the time "TsearchMpp"
has expired.

0 W …

25 000 W

15 000 W

TsearchMpp

*

Time for a new search for
the MPP
If the value is below the
value "PsearchMpp" for
the time "TsearchMpp",
the inverter starts
searching for the MPP.

60 s … 3 600 s

600 s