beautypg.com

3 displaying the daily energy yield values, 4 deleting the daily energy yield values, Displaying the daily energy yield values – SMA SC 400HE User Manual

Page 34: Deleting the daily energy yield values

background image

4 Sunny Central Control

SMA Solar Technology AG

34

SC4-63HE-BE-BEN103280

Operating Manual

4.3.3 Displaying the Daily Energy Yield Values

1. Select Long-Term Data > Energy Yield. The daily values are compiled monthly.
2. Select the month and confirm by pressing [ENTER].

4.3.4 Deleting the Daily Energy Yield Values

1. Select Device Set-up > Parameters > Param.-Function.

☑ The display flashes.

2. Select Del. Daily Value and confirm by pressing [ENTER].

4.3.5 Adding Other Measurement Channels to Long-Term Data List

The Sunny Central Control displays 14 measurement channels in the default settings.

1. Select Device Set-up > Data archives >

Chan. Select. > SC...SCCXXX.
☑ The Sunny Central Control displays all

measurement channels (see section
8 "Sunny Central Control Measurement
Channels", page 89). The measurement
channels displayed in the menu Long-Term Data > Meas. Chn. > SC...SCXXX are
marked by a dot.

2. Select the measurement channel and confirm by pressing [ENTER]. In the future, the

measurement channel is then displayed under Long-Term Data > Meas. Chn. > SC...SCXXX.
☑ A dot appears before the selected measurement channel and it is added to the long-term

data list.

3. After exiting the menu, confirm the security prompt twice with [ENTER].

☑ Another measurement channel is added to the long-term data list.

4.3.6 Resetting the Long-Term Data List of the Measurement

Channels to the Factory Setting

1. Enter password (see section 4.2.2 "Entering the Password", page 32).
2. Select Device Set-up > Parameters > Param.-Function.

☑ The display flashes.

3. Select default chan. and confirm by pressing [ENTER].

☑ The line stops flashes.

4. Press [ENTER].

This manual is related to the following products: