7 Troubleshooting

SMA Solar Technology AG

84

SC4-63HE-BE-BEN103280

Operating Manual

220

Error text:
Release- or Reset-Signal faulty

Error type 2

Failure cause:
The release signal or confirmation signal of the inverter bridge is faulty.
Corrective measures:
Contact the SMA Serviceline if the error persists.

222

Error text:
Ambient temperature

Error type 2

Failure cause:
The ambient temperature is higher than 51°C.
Corrective measure:

• Check the cooling concept.
• Check the fans.
• Check the ambient conditions.
• Check the sensor.

281

Error text:
Ground fault or SPD defect

Error type 2

Failure cause:
GFDI has tripped. There is a ground fault.
Corrective measure:
Check the PV plant for a ground fault.

400

Error text:
Internal failure of inverter bridge

Error type
2/3

Failure cause:
Internal inverter bridge failure (e.g., symmetry fault, board voltage, undertemperature,
sensor breakage).
Corrective measures:
Contact the SMA Serviceline if the error occurs frequently.

No.

Description

This manual is related to the following products: