9 Parameters

SMA Solar Technology AG

100

SC4-63HE-BE-BEN103280

Operating Manual

9.9  Start Requiremt

*Only modify these parameters after consultation with SMA Solar Technology AG.

9.10 Shut-down Requ.

*Only modify parameters after consultation with SMA Solar Technology AG.

Name

Description

Value /
range

Explanation

Default
value

Operating
Mode

*

Condition for starting up the
inverter

MPP

Maximum power point
tracking

MPP

VconstSet Target value for constant

voltage operation

VconstSet

Target value for constant
voltage operation

300 V …

700 V

600 V

VpvStart

PV voltage that must be
exceeded for the inverter to
switch into feed-in operation

300 V …

1 000 V

SC 400HE-11

600 V

300 V …

1 000 V

SC 500HE-11

600 V

300 V …

1 000 V

SC 630HE-11

650 V

Tstart

Time span until the inverter
switches from the "Waiting"
operating state to "Startup"

1 s …

600 s

90 s

Twait

Time span until the inverter tries
to start up again after 3 failed
attempts

0 s …

18 000 s

600 s

Name

Description

Value / range

Default
value

PpvStop

*

PV power before the inverter switches into the
"Waiting" operating state after time "TStop".

0 W … 10 000 W

5 000 W

Tstop

Time span until the inverter switches into the
"Startup" operating state if the array power
"Ppv" < "PpvStop"

60 s … 600 s

60 s

This manual is related to the following products: