7 Troubleshooting

SMA Solar Technology AG

86

SC4-63HE-BE-BEN103280

Operating Manual

410

Error text:
IGBT Stack Error Sum

Error type 3

Failure cause:
Internal inverter bridge fault (e.g., DC overvoltage, overtemperature, defective driver,
overcurrent).
Corrective measures:

• Contact the SMA Serviceline if the error occurs frequently.
• The unit can be switched back on in 30 minutes.

Information:

• If the failure poses a danger to the PV plant or the Sunny Central, the Sunny Central

switches into the "Waiting" operating state for 30 minutes.

411

Error text:
IGBT-Overcurrent or UVW-Phase Error ADAPSCP

Error type 3

Failure cause:
Internal failure of the inverter bridge.
Corrective measures:
Contact the SMA Serviceline if the error occurs frequently.

412

Error text:
Overcurrent

Error type 3

Failure cause:
Internal failure of the inverter bridge.
Corrective measures:
Contact the SMA Serviceline if the error occurs frequently.

413

Error text:
Internal stack monitoring tripped

Error type 4

Failure cause:
Internal failure of the inverter bridge.
Corrective measures:

• Contact the SMA Serviceline if the error occurs frequently.

Information:

• Up to three confirmations are possible, afterwards the unit must be reset via the key

switch.