Test run and program run

16.3 T

e

st r

u

n

Setting a tilted working plane for the test run

You can use this function on machines, where you want to define the
working plane by manually setting the machine axes.

Select the Test Run operating mode

Choose the program you want to test

Select MOD functions

Select the menu for defining the working plane

To activate or deactivate the function, press the ENT

key

Use the active rotary axis coordinates from the

machine mode of operation, or

Position the highlight on the desired rotary axis with

the arrow keys and enter the rotary-axis value to be
used by the TNC in the simulation

This function must be enabled by your machine
manufacturer.

If the function has been enabled by your machine
manufacturer, then the TNC does not deactivate the "Tilt
the working plane" function when you select a new
program.

If you simulate a program that does not contain a TOOL
CALL

block, then the axis you have activated for manual

probing in the Manual Operation mode is used by the TNC
as tool axis.

Ensure that the active kinematics in the test run is suitable
for the program you want to test. Otherwise, the TNC may
issue an error message.