109

3.2 Cr

eating and wr

iting pr

ogr

a

ms

Possible feed rate input

Functions for setting the feed rate

Soft key

Rapid traverse, non-modal. Exception: If defined
before an APPR block, FMAX is also in effect for
moving to an auxiliary point (see "Important
positions for approach and departure" on page
222)

Traverse feed rate automatically calculated in
TOOL CALL

Move at the programmed feed rate (unit of
measure is mm/min or 1/10 inch/min). With
rotary axes, the TNC interprets the feed rate in
degrees/min, regardless of whether the program
is written in mm or inches

With FT, instead of a speed you define a time in
seconds (input range 0.001 to 999.999 seconds),
in which the programmed path is to be traversed.
FT

is effective only blockwise

With FMAXT, instead of a speed you define a time
in seconds (input range 0.001 to 999.999
seconds), in which the programmed path is to be
traversed. FMAXT is effective only for keyboards
with a rapid traverse potentiometer. FMAXT is
effective only blockwise

Define the feed per revolution (units in mm/rev or
inch/rev). Caution: In inch-programs, FU cannot
be combined with M136

Define the tooth feed (units in mm/tooth or
inch/tooth). The number of teeth must be defined
in the tool table in the CUT. column

Functions for conversational guidance

Key

Ignore the dialog question

End the dialog immediately

Abort the dialog and erase the block