beautypg.com

Activating feed-rate limitation, Additional status displays, 4 f u nctional saf e ty fs (option) – HEIDENHAIN iTNC 530 (60642x-03) User Manual

Page 573

background image

HEIDENHAIN iTNC 530

573

14.4 F

u

nctional saf

e

ty FS (option)

Activating feed-rate limitation

When the F LIMITED soft key is set to ON, the TNC limits the
maximum permissible axis speeds to the specified, safely limited
speed. The valid speeds for the active mode of operation are shown
in the Safety-MP table (see "Overview of permitted feed rates and
speeds" on page 572).

Select the Manual Operation mode

Scroll to the last soft-key row

Switch on/off feed rate limit

Additional status displays

On a control with functional safety FS, the general status display
contains additional information about the current status of safety
functions. The TNC shows this information as operating statuses of
the status displays T, S and F

The TNC shows the active safety-related mode of operation with an
icon in the header to the right of the operating mode text. If the SOM_1
mode is active, the TNC does not display any icon.

Status display

Short description

STO

Energy supply to the spindle or a feed drive is
interrupted.

SLS

Safely-limited speed: A safely limited speed is
active.

SOS

Safe operating stop: Safe operating stop is
active.

STO

Safe torque off: Energy supply to the motor is
interrupted.

Button

Safety-related operating mode

SOM_2

mode active

SOM_3

mode active

SOM_4

mode active