.15 F

reely definable tables

FN 27: TABWRITE: Writing to a freely definable
table

After you have opened a table with FN 26: TABOPEN, you can use the
function FN 27: TABWRITE to write to it.

You can define and write up to 8 column names in a TABWRITE block.
The column names must be written between quotation marks and
separated by a comma. You define the values that the TNC is to write
to the respective column with Q parameters.

Example:

You wish to write to the columns "Radius," "Depth" and "D" in line 5 of
the presently opened table. The values to be written in the table must
be saved in the Q parameters Q5, Q6 and Q7.

Note that by default the FN 27: TABWRITE function writes
values to the currently open table also in the Test Run
mode. Using the FN17 ID990 NR2 IDX16=1 function you can
specify that the TNC performs the FN27 function only in the
Program Run modes.

You can write only to numerical table fields.

If you wish to write to more than one column in a block,
you must save the values under successive Q parameter
numbers.

53 FN0: Q5 = 3.75

54 FN0: Q6 = –5

55 FN0: Q7 = 7.5

56 FN 27: TABWRITE 5/"RADIUS,DEPTH,D" = Q5