Tool usage test

The following are prerequisites for a tool usage test:

Bit 2 of the machine parameter must be set to 7246=1

The machining timer must be active in the Test Run operating mode

A simulation of the plain language program must have been
completed in the Test Run mode

Settings for the tool usage test

To be able to influence the behavior of the tool usage test, a form is
available, which you can call as follows:

Select the Program Run, Single Block mode or the Program Run, Full
Sequence mode.

Press the Tool Usage soft key: The TNC shows a soft-key row with
functions for the usage test.

Press the SETTINGS soft key: The TNC displays the form with the
available settings.

You can define the following settings separately for Program Run,
Full Sequence / Single Block

and the Test Run.

Do not generate tool-usage file

setting

The TNC does not generate a tool usage file

Generate tool-usage file once

setting

The TNC generates a tool usage file once with the next NC start or
start of the simulation. Then the TNC automatically deactivates the
Do not generate tool-usage file

mode to prevent the usage file

from being overwritten during further NC starts

Generate new tool usage file after changes or as needed

(basic

setting):
The TNC generates a tool usage file with every NC start or every
start of the test run. The setting ensures that the TNC also
generates a new tool-usage file after program changes

The tool usage test function must be enabled by your
machine manufacturer. Refer to your machine manual.

If there is no valid tool usage file available and the
machining time calculation is deactivated, then the TNC
creates a tool usage file with a default time of 10s for each
tool usage.