beautypg.com

HEIDENHAIN iTNC 530 (60642x-03) User Manual

Page 604

background image

604

Manual operation and setup

14.9 D

a

tu

m set

ting with a t

o

uc

h pr

obe

Using touch probe functions with mechanical
probes or dial gauges

If you do not have an electronic touch probe on your machine, you can
also use all the previously described manual touch probe functions
(exception: calibration function) with mechanical probes or by simply
touching the workpiece with the tool.

In place of the electronic signal generated automatically by a touch
probe during probing, you can manually initiate the trigger signal for
capturing the probing position by pressing a key. Proceed as follows:

Select any touch probe function by soft key

Move the mechanical probe to the first position to be

captured by the TNC

Confirm the position: Press the actual-position-

capture key for the TNC to save the current position

Move the mechanical probe to the next position to be

captured by the TNC

Confirm the position: Press the actual-position-

capture key for the TNC to save the current position

If required, move to additional positions and capture

as described previously

Datum

: In the menu window, enter the coordinates of

the new datum, confirm with the SET DATUM soft
key, or write the values to a table (see "Writing the
measured values from touch probe cycles in datum
tables", page 584
, or see "Writing the measured
values from touch probe cycles in the preset table",
page 585)

To terminate the probe function, press the END key