beautypg.com

3 fixt ur e monit o ri ng (dcm sof tw a re option) – HEIDENHAIN iTNC 530 (60642x-03) User Manual

Page 412

background image

412

Programming: Special functions

1

1

.3 Fixt

ur

e monit

o

ri

ng (DCM

sof

tw

a

re

option)

Set-up clearance

:

Setup clearance to the measuring point that the TNC
should maintain during pre-positioning. Input range
0 to 99999.9999

Tolerance

:

Maximum permissible deviation between nominal
and actual position of the respective test points. Input
range 0 to 99999.999. If the test point is out of
tolerance, the TNC issues an error message

Tool number/tool name

:

Tool number (or name) of the touch probe. Input
range 0 to 30000.9 if a number is entered; maximum
16 characters if a name is entered. If entering a tool
name, enter it between single quotation marks

Confirm the entries: The TNC generates the test

program, shows the name of the test program in a
pop-up window and asks whether you want to run the
test program

Answer with NO if you want to run the test program

later, and with YES if you want to run it now

If you have confirmed with YES, the TNC changes to

the Full Sequence mode and automatically selects
the generated program

Start the test program: The TNC prompts you to

manually pre-position the touch probe so that it is
located at clearance height. Follow the instructions in
the pop-up window

Start the measuring process: The TNC moves to each

test point one after the other. With a soft key you
specify the positioning strategy. Conform with NC
start each time

At the end of the test program the TNC displays a pop-

up window with the deviations from the nominal
position. If a test point is out of tolerance, the TNC
issues an error message in the pop-up window