beautypg.com

Storing measured values in the pallet preset table, 6 using t o uc h-pr obes – HEIDENHAIN iTNC 530 (60642x-03) User Manual

Page 586

background image

586

Manual operation and setup

14.6 Using t

o

uc

h-pr

obes

Storing measured values in the pallet preset
table

Select any probe function

Enter the desired coordinates of the datum in the appropriate input
boxes (depends on the touch probe cycle being run)

Enter the datum number in the Number in table: input box

Press the ENTER IN PALLET PRES. TAB. soft key. The TNC saves
the datum in the preset table under the entered number

You use this function for determining pallet datums. This
function must be enabled by your machine tool builder.

In order to store a measured value in the pallet preset
table, you must activate a zero preset before probing. A
zero preset consists of the entry 0 in all axes of the preset
table!