beautypg.com

HEIDENHAIN iTNC 530 (60642x-03) User Manual

Page 597

background image

HEIDENHAIN iTNC 530

597

14.9 D

a

tu

m set

ting with a t

o

uc

h pr

obe

Corner as datum—using points that were
already probed for a basic rotation

Select the probe function: Press the PROBING P soft

key

Touch points of basic rotation ?

: Press ENT to

transfer the touch point coordinates

Position the touch probe at a position near the first

touch point of the side that was not probed for basic
rotation

Select the probe direction by soft key

Probing: press the NC Start button

Position the touch probe near the second touch point

on the same workpiece edge

Probing: press the NC Start button

Datum:

Enter both coordinates of the datum in the

menu window, confirm with the SET DATUM soft
key, or write the values to a table (see "Writing the
measured values from touch probe cycles in datum
tables", page 584, or see "Wri
ting the measured
values from touch probe cycles in the preset table",
page 585, or
see "Storing measured values in the
pallet preset table", page 586
)

To terminate the probe function, press the END key

Corner as datum—without using points that
were already probed for a basic rotation

Select the probe function: Press the PROBING P soft key

Touch points of basic rotation?

: Press NO ENT to ignore the

previous touch points. (The dialog question only appears if a basic
rotation was made previously.)

Probe both workpiece edges twice

Datum

: Enter the coordinates of the datum and confirm your entry

with the SET DATUM soft key, or write the values to a table (see
"Writing the measured values from touch probe cycles in datum
tables", page 584,
or see "Writing the measured values from touch
probe cycles in the preset table", page 585,
or see "Storing
measured values in the pallet preset table", page 586
)

To terminate the probe function, press the END key

P

X=?

Y=?

X

Y

P

X

Y