beautypg.com

Configuring a cross-connect, Required.) – H3C Technologies H3C S6800 Series Switches User Manual

Page 341

background image

328

Step Command

Remarks

2.

Enter Layer 2 Ethernet
interface view or Layer 2

aggregate interface view.

Enter Layer 2 Ethernet interface
view:

interface interface-type

interface-number

Enter Layer 2 aggregate

interface view:

interface bridge-aggregation
interface-number

N/A

3.

Create a service instance

and enter service instance
view.

service-instance instance-id

By default, no service instance is
created.

4.

Configure match criteria for
the service instance.

Match all incoming packets:

encapsulation default

Match incoming packets with

any VLAN ID or no VLAN ID:

encapsulation { tagged |

untagged }

Match incoming packets with a

specific outer VLAN ID:

encapsulation s-vid vlan-id
[ only-tagged ]

By default, no match criteria are
configured for the service instance.
To match packets with VLAN IDs on
an interface, you must first create the

VLANs, and then assign the interface
to the VLANs.

Configuring a cross-connect

Step Command

Remarks

1.

Enter system view.

system-view

N/A

2.

Create a cross-connect group

and enter cross-connect group
view.

xconnect-group group-name

By default, no cross-connect group
is created.

3.

(Optional.) Configure a
description for the

cross-connect group.

description text

By default, no description is
configured for the cross-connect

group.

4.

(Optional.) Enable the

cross-connect group.

undo shutdown

By default, the cross-connect group
is enabled.

5.

Create a cross-connect and

enter cross-connect view.

connection connection-name

By default, no cross-connect is
created.

6.

Set an MTU for the PW.

mtu mtu

The default MTU is 1500 bytes.
The two PEs on an LDP PW must
have the same MTU configured for

the PW. Otherwise, the PW cannot
go up.