beautypg.com

5 example: to configure heating and cooling, Example: to configure heating and cooling – Super Systems 3 Series User Manual

Page 60

background image

Operations Manual

Series 3

60

11.5

Example: To Configure Heating and Cooling

Enter configuration level as described. Then

Do This

The Display You Should

See

Additional Notes

1.

Press

as many times as necessary to

select ‘C T R L’

2.

Press

to scroll to ‘C T R LH ’

3.

Press

or

to select the Heating

Type

Heating Type choices are:
Pid

PID (3 term) control

on.of

On/Off control

oFF

No heating output configured

4.

Press

to select ‘C T R L. C ’

5.

Press

or

to select the Cooling

Type

Cooling Type choices are:
oFF

No cooling output configured

PId

PID (3 term) control

on.of

On/Off control

6. Press

to select ‘C T R L. A ’

7.

Press

or

to ‘rev’

Control Action choices are:
rev

Reverse - heating control

Dir

Direct - cooling only control

8.

Press

to scroll to ‘P B . U N T ’

9. Press

or

to choose units

Proportional Band Units choices are:
EnG

Engineering units

Perc

Percentage

10. Continue to select parameters using

for example ‘O P . H I’

11. Press

or

to change their values

When PID control is selected, this places a limit on the
output demand from the PID which can be applied to the
heating circuit.
‘OP.LO’ can be set up in the same way if required.
If on/off control is selected these parameters do not apply.
They are replaced by ‘HYST.H’ and ‘HYST.L’ to set the
difference between the output switching off to switching
on.