Measurement Computing WaveBook rev.5.3 User Manual
Page 69

WaveBook User’s Manual
897895
System Examples 3-9
Example 2 (continued):
2nd WaveBook/516A Sub-System -- Includes the WBK25 Ethernet Module and the 3 components beneath it.
1. Power Supply - To the second WaveBook/516A’s POWER IN DIN 5 connector, +10 VDC to
+30 VDC, typically from a TR-40U power adapter.
2. Power Supply – From the second WaveBook/516A’s POWER OUT DIN 5 connector to the
WBK25’s POWER IN DIN 5 connector via a CA-115 power cable.
3. Power Supply – To the WBK18’s POWER IN DIN 5 connector, +10 VDC to +30 VDC,
typically from a TR-40U power adapter.
4. Power Supply – To the second WBK10A’s POWER IN DIN 5 connector, +10 VDC to +30
VDC, typically from a TR-40U power adapter.
5. Expansion – From the second WaveBook/516A’s PARALLEL PORT to the WBK25 Ethernet
Interface Module’s EXPANSION PORT 2. The connection is made via a 25-pin CA-35-12 cable.
6. Expansion Control – From the second WaveBook/516A’s EXPANSION CONTROL to the
WBK18’s EXPANSION CONTROL IN. Connection is via a 15-pin CA-129 cable.
7. Expansion Control – From the WBK18’s EXPANSION CONTROL OUT to the second
WBK10A’s EXPANSION CONTROL IN. Connection is via a 15-pin CA-129 cable.
8. Expansion Signal – From the second WBK10A’s EXPANSION SIGNAL OUT to the WBK18’s
EXPANSION SIGNAL IN. Connection is via a BNC coaxial CA-150 cable.
9. Expansion Signal – From the WBK18’s EXPANSION SIGNAL OUT to the second
WaveBook/516A’s EXPANSION SIGNAL IN. Connection is via a BNC coaxial CA-150 cable.
Note: Ethernet and Synchronization aspects for Multiple WaveBooks, example 2, are dealt with in the list
of lines and connections for the first WaveBook/516A Sub-System.