Power Out. The pinout at the right applies to the
two POWER OUT DIN5 connectors. The DBK34A
package includes a short connecting cable to
connect to the powered device. This cable connects
the POWER OUT connector on the DBK34A and
to the POWER IN connector on the acquisition
device; e.g., ZonicBook/618E, WaveBook,
LogBook, DaqBook, or WBK/DBK module.

DIN5 Power Output Connector

(2 per DBK34A)


Indicators.
Three front-panel LED indicators provide power and charging status information.

LED Indicators & Descriptions

MAIN POWER

Lights when the DBK34A power input is connected to a source of at least 12.25 VDC

CHARGING

Lights when the internal batteries are being fast-charged at a rate of 0.1 amp/cell or

greater.

DISCHARGING

Lights when internal batteries (or auxiliary batteries) are discharging at a rate of 0.25A

or greater.


Runtime. Approximate runtime under various loads can be computed from the storage capacity
(5 A-hr in 12 V mode; 2.5 A-hr in 24 V mode) and the load (main unit and other DBKs).


The following Load Wattage vs. Hours graph is for a typical new battery that is fully charged.

Charging: In general, lead-acid batteries [and related Gel-Packs] require charging at 120% of drain energy
(e.g., the 5 A-hr DBK34A requires a charge equal to or greater than 6 A-hr). Charging times vary; but 4 to
5 hours at 14 V is typical for a completely discharged battery; after which, charging may continue
indefinitely.

Note that 16 to 18 VDC at the power input is required for optimal charging.

CAUTION

Voltage applied to a DBK34A must not exceed 30 VDC.