Calibrate mode, Odometer calibration, 2 select calibrate mode – Gasboy Fuel Point Vehicle Module User Manual
Page 43: 3 hold the programmer near the vehicle's t-ring, Calibrate mode -15, Important information

MDE-4524A Vehicle Module Programming Manual· May 2006
Page 5-15
Programmer Operating Modes
Operation
Calibrate Mode
Calibrate mode is used initially to automatically calculate the odometer ratio if it is not known.
It is also used periodically to adjust for slight variations between the odometer and the VM. If
any of the counter fields is used for engine hours, you do not need to perform calibration, as
the VM keeps very accurate time.
Odometer Calibration
1
Turn on the Programmer. Refer to
“Turning On Programmer” on page 5-1
.
2
Select Calibrate mode.
YES
ENTER
3
DEF
1 - PROG 2 - EDIT
3 - CAL 4 - DIAG ?
3
Hold the Programmer near the vehicle's T-Ring.
HOLD PROGRAMMER
NEAR TANK RING
The Programmer cannot calibrate a VM with engine hours when the vehicle is
running. Ensure that the vehicle is shut off during Calibrate mode.
IMPORTANT INFORMATION
4
When communication is established, a series of beeps will be heard. Continue to hold the
Programmer near the T-Ring. It takes about 5 seconds to read the data.
TRANSMITTING
PLEASE WAIT
5
The Programmer prompts you to select the VM counter which you want to update. Since the
odometer is typically connected to counter 1, select 1
ST
.
ENTER
YES
0
QZ
SEL CALIB: 1ST - 0
2ND - 1 BOTH - 2 ?