12 this is a dual vm, 13 the second field is hours, Important information – Gasboy Fuel Point Vehicle Module User Manual
Page 37

MDE-4524A Vehicle Module Programming Manual· May 2006
Page 5-9
Programmer Operating Modes
Operation
11
Enter 1 as the ratio. This allows a quick way to test if the VM is recording pulses, without
having to drive very far.
YES
ENTER
1
ENTER ODO RATIO:
1????
12
This is a dual VM.
YES
ENTER
1
DUAL COUNTERS 1
NO - 0 YES - 1
13
The second field is hours.
YES
ENTER
1
SEL: ODOMETER - 0
SCND 1
HOURS - 1
14
Since you want to test the installation, enter an engine hours reading that ends in 0.9 (0.9 hours
equals 54 minutes). That way, you only have to wait 6 minutes to verify that the engine hours
connection is functioning. The correct starting hours reading will be loaded after testing.
YES
ENTER
1
2
ABC
WXY
9
3
DEF
PRESET TIME [2]
[H] ????123.9
15
Hold the Programmer near the vehicle's T-Ring. If the vehicle is equipped with two T-Rings,
perform the programming at one ring, then use the second ring while Testing the Programmed
VM steps. This allows testing of both ring circuits.
HOLD PROGRAMMER
NEAR TANK RING
The Programmer cannot program a VM for engine hours when the vehicle is
running. Ensure the vehicle is shut off during Programming.
IMPORTANT INFORMATION
IMPORTANT INFORMATION