LCS-4 L-Band Combiner Switch

Revision 1

Specifications

MN/LCS4.IOM


Table B-1. General Specification (Continued)

10 MHz Reference:

To BUC

To LNB


Via TX (BUC)/RX (LNB) center conductor, selectable ON/OFF

0

± 3 dBm

-3

± +3 dBm

Spurious Emissions TX Toward BUC or
RX Toward Demodulator

-55 dBc over 55 MHz to 2.2 GHz measured in a 4 kHz BW with
a CW source.

TX Output Level with TX Inputs Terminated

-60 dBm or less over 800 MHz to 2.2 GHz measured in a 4kHz
BW.

TX Output with Modulated Carrier with Unused Ports
Terminated.

-55 dBc over the operating frequency range measured in a
4 kHz BW
-60 dBm over 1610 to1 680 MHz in a 4 kHz BW for Inmarsat
applications.

RF Input/RF Output Overload

All TX and RX inputs or outputs shall sustain +13 dBm per port
without damage.

FSK Communications to BUC

Pass through from modem via ports 1 or 4 for primary and
backup access
Protocol: Interoperable with the SierraCom or Terrasat BUC.

FSK Drivers/Receivers

Hardware is provided – software support for FSK is future.

Outdoor RF Switch Control Connector

Indoor circuitry to drive outdoor BUC and LNB RF Switched.

Remote Port Connector

RS-232 and RS-485 Control or Unit.

Relay Fault Status Connector

ODU/BUC A ODU/BUC B/LNB A/LNB B and Combiner Switch
Unit.

BUC/LNB Fault Input

BUC A/B FLT inputs
LNB A/B FLT
Separate FLT enable inputs for BUC and LNB

DIP Switch Sensing (4)

1 switch indicates EXT ODU/BUC Fault contact inputs
1 switch indicates EXT LNB fault contact inputs
2 switches - future

Prime Power:

AC Inlet A
AC Inlet B


85 to 264 VDC, 47 to 63 Hz, 60W maximum, excluding BUC PS
85 to 264 VDC, 47 to 63 Hz, 60W maximum, excluding BUC PS

Optional Prime 48 VDC Power:

DC Inlet A
DC Inlet B


38 to 64 VDC, 60W maximum, excluding BUC PS
38 to 64 VDC, 60W maximum, excluding BUC PS

LNB Voltage via 2 RX Connectors

18 VDC at 500 mA, maximum. Selectable ON OFF via M&C
control. Voltage and current monitored with window limit
sensing. Short circuit protected.

BUC Voltage via 2 RX Connectors

Optional 24 to 48 VDC BUC power. Selectable ON/OFF via
M&C control. Voltage and current monitored with window limit
sensing. Short circuit protected.

Power Consumption:

100W BUC PS
150W BUC PS


220W maximum (Estimated)
300W maximum (Estimated)









B-2