beautypg.com

Chp5.pdf, Block up converter, General – Comtech EF Data LCS-4 User Manual

Page 41: C-band redundant buc assembly procedure, Chapter 5. block up converter, 2 c-b, Buc a

background image

Chapter 5. BLOCK UP

CONVERTER

5.1 G

ENERAL

The Block Up Converter (BUC) translates the L-Band carrier output from the IDU (in the 950 to
1750 MHz range) to C- or Ku-Band frequencies typically between:

• C-Band: 5.845 and 6.425 GHz and amplifies the carrier to the desired TX power level.

• Ku-Band: 14.0 and 14.5 GHz and amplifies the carrier to the desired TX power level.

The local oscillator of the BUC locks to the 10 MHz reference signal from the IDU in order to
provide an accurate frequency translation. In the event the BUC cannot lock to the 10 MHz
reference, the output carrier is muted to prevent interference with adjacent carriers.

5.2 C-B

AND

R

EDUNDANT

BUC A

SSEMBLY

P

ROCEDURE

Part No.

Nomenclature

QTY

PL/9528-1

BUC Assembly, C-Band

1

PL/9526-1

Mounting Kit, C-Band

1



5–1