beautypg.com

External buc/lnb fault input, Buc/lnb f, Xternal – Comtech EF Data LCS-4 User Manual

Page 19: Ault, Nput

background image

LCS-4 L-Band Combiner Switch

Revision 1

Introduction

MN/LCS4.IOM

1.5 E

XTERNAL

BUC/LNB F

AULT

I

NPUT

Use of this connector is optional. This connector permits fault inputs from ODU/BUC or
LNB that have fault contacts for fault indication. Normally, this connector is used in
applications where the ODU/BUC power supply or LNB power supply is external to the
LCS-4 to permit a means of indicating a fault to the LCS-4 so that ODU/BUC or LNB
switchover still occurs.

The external fault inputs are enabled in one of two ways:

1. By grounding the BUC Input Enable and /or the LNB Input Enable.
2. Activating the DIP-switches that control the BUC Input Enabled and/or LNB

Input Enable.

J21, 9-pin D Female

Pin #


Signal Name

Signal

Direction


Description

1
2
8

BUCA_FLT
BUCB_FLT_BUF
BUC_FLT_EN

I
I
I

External BUC A Fault. (Grounded is OK)
External BUC B Fault. (Grounded is OK)
External BUC Fault Input Enable – with
GND

6
7
3

LNBB_FLT
LNBB_FLT_BUF
LNB_FLT_EN

I
I
I

External LNB A Fault (Grounded is OK)
External LNB B Fault (Grounded is OK)
External LNB Fault Input Enable – with
GND

4,5,9 GND

GND

Ground

1–5