Comtech EF Data LCS-4 User Manual
Page 71

LCS-4 L-Band Combiner Switch
Revision 1
Remote Control Operation
MN/LCS4.IOM
A-7
Parameter
Type
Command
(Instruction
Code and
qualifier)
Arguments
for Cmd or
Response
to Query
Description of Arguments
Note that all arguments are ASCII
numeric codes between 48 and 57.
Response to
Command
(Target to
Controller)
Query
(Instruction
code and
qualifier)
Response to query
(Target to Controller)
BUC Power
Supply A
Enable
BSA=
1 byte,
value of 0,1
Command or Query.
BUC A Power Supply, where:
0=Disabled
1=Enabled
Example: BSA=1
Parameter 2 of SGC Command
BSA= (message ok)
BSA? (Received ok,
but invalid
arguments found)
BSA*(message ok,
but not permitted in
current mode)
BSA? BSA=x (same format as command
arguments)
BUC Power
Supply B
Enable
BSB=
1 byte,
value of 0,1
Command or Query.
BUC B Power Supply, where:
0=Disabled
1=Enabled
Example: BSB=1
Parameter 3 of SGC Command
BSB= (message ok)
BSB? (Received ok,
but invalid
arguments found)
BSB*(message ok,
but not permitted in
current mode)
BSB? BSB=x (same format as command
arguments)
BUC A
Reference
Oscillator
Enable
BRA=
1 byte,
value of 0,1
Command or Query.
BUC A reference Oscillator, where:
0=Disabled
1=Enabled
Example: BRA=1
Parameter 4 of SGC Command
BRA= (message ok)
BRA? (Received ok,
but invalid
arguments found)
BRA*(message ok,
but not permitted in
current mode)
BRA? BRA=x (same format as command
arguments)
BUC B
Reference
Oscillator
Enable
BRB=
1 byte,
value of 0,1
Command or Query.
BUC B reference Oscillator, where:
0=Disabled
1=Enabled
Example: BRB=1
Parameter 4 of SGC Command
BRB= (message ok)
BRB? (Received ok,
but invalid
arguments found)
BRB*(message ok,
but not permitted in
current mode)
BRB? BRB=x (same format as command
arguments)
BUC Fault
Logic
BFL=
1 byte,
value of 0,1
Command or Query.
BFL controls whether or not the Summary Fault Relay
(SFR) is affected by the BUC Volt or Current window
monitor, where:
0=A BUC Volt/Current Fault does not effect the SFR,
1=A BUC Volt/Current Fault will effect the SFR.
Example: BFL=1
Parameter 8 of SGC Command
BFL= (message ok)
BFL? (received ok,
but invalid
arguments found)
BFL?
BFL=x (same format as
command arguments)
BUC A
Current
Window
BCA=
2
bytes,
numerical
Command or Query.
BUC A Current Monitor Window, this command allows
the user to set the alarm window in
±% of
DAT= (message ok)
DAT? (received ok,
but invalid
arguments found)
DAT?
DAT=xx.xx
(same format as command
arguments)