Mounting, Ounting – Comtech EF Data LCS-4 User Manual
Page 22

LCS-4 L-Band Combiner Switch
Revision 1
Installation
MN/LCS4.IOM
2.2
M
OUNTING
If the LCS-4 is to be mounted in a rack, ensure that there is adequate clearance for
ventilation, particularly at the sides. In rack systems where there is high heat dissipation,
forced air-cooling must be provided by top and bottom mounted fans or blowers.
UNDER NO CIRCUMSTANCE should the highest internal rack temperature be
allowed to exceed 50
°C (122° F).
Install optional installation bracket (Figure 2-1) using mounting kit, KT/6228-1.
Optional: Mounting Kit, KT/6228-1
Quantity
Part Number
Description
2 FP/6138-1
Bracket,
Rear
Support
4
HW/10-32x1/2RK
Bolt, #10 Rack
2 HW/10-32HEXNUT
Nut,
#10
Hex
2 HW/10-32FLT
Washer,
#10
Flat
2
HW/10-32x1/4SHC
Screw, Socket 10-32 x 1/4inch
The tools required for this installation are a medium Phillips
screwdriver and a 5/32-
inch SAE Allen Wrench
.
Refer to the Figure 2-1, and then install the LCS-4 rear support brackets as follows:
1. Install the rear support brackets onto the mounting rail of the rack. Fasten with
the bracket bolts.
2. Mount the LCS-4 into the equipment rack ensuring that the socket heads
engage into the LCS-4 slots of the rear support brackets,
3. Fasten the provided #10 socket head screws to the rear-side mounting slots on
either side of the chassis and secure with #10 flat washers and #10 hex nuts.