LCS-4 L-Band Combiner Switch

Revision 1

Remote Control Operation

MN/LCS4.IOM


A-15

Parameter
Type

Command
(Instruction
Code and
qualifier)

Arguments
for Cmd or
Response
to Query

Description of Arguments
Note that all arguments are ASCII
numeric codes between 48 and 57.

Response to
Command
(Target to
Controller)

Query
(Instruction
code and
qualifier)

Response to query
(Target to Controller)

Summary
Fault Status

N/A

1

byte,

value of 0,1

Query only.
Used to Query the status of the LCS-4 Summary Fault
Relay.
Where:
0=OK
1=FT
Example: SFS=0

N/A

SFS?

SFS=x

(same format as command
arguments)

Terminal
Status
Change

N/A

1

byte,

value of 0,1

Query only.
Used to Query the status of the Terminal Status.
Where:
0=No Change in Status
1=Change in Status
Example: TSC=0

N/A

TSC?

TSC=x

(same format as command
arguments)

Restore
Factory
Defaults

RST=

1

byte,

value of 1

Command only.
Used to restore unit setting to factory default.
Example: RST =1
Following is a list of restore values:
RAM=0(manual)
MOD=1(independent switching)
SRO=Factory setting
VPC=1(On)
BCA, BCB, LCA, LCB=99 (Disabled)
CBA,CB,CLA,CLB=0 (Zero out Cal Values)
BSA, BSB, LSA, LSB=0 (PS Off)
BRA, BRB, LRA, LRB=0 (Ref Off)
BFL, LFL=0 (Summary Fault Unaffected)
RFL=0 (EXT REF Not Monitored)
CLD=0 (Disabled)
FSM=1 (Modem 1 FSK Control)
STT, SRT=0 (Combiner)
UPC=0 (Passthru)
ATT=2695 (Mid Point)

RST= (message ok)
RST? (received ok,
but invalid
arguments found)

N/A