LCS-4 L-Band Combiner Switch

Revision 1

Remote Control Operation

MN/LCS4.IOM


A.2.1.5 M

ESSAGE

A

RGUMENTS

Arguments are not required for all messages. All arguments are ASCII codes for the
characters 0 to 9 (ASCII 48 to ASCII 57), period (ASCII 46) and comma (ASCII 44).

A.2.1.6 E

ND

O

F

P

ACKET

Controller to Target: This is the Carriage Return character (ASCII code 13)
Target to Controller: This is the two-character sequence Carriage Return, Line Feed.
(ASCII code 13, and code 10.)

Both indicate the valid termination of a packet.

A.3 C

OMMANDS OR

R

ESPONSES

The commands and responses are provided to assist the technician in monitoring and
controlling the unit.

A-6