Stored faults, A.8 stored faults – Comtech EF Data SMS-301 User Manual
Page 92

Remote Control Operation
SMS-301 Redundancy Switch
A-10
Rev. 3
A.8 Stored
Faults
Information on stored faults is returned when requested. If no stored fault exists for a
given fault number, the words “NO Fault” will be returned instead of the normal
time/date status information.
The following symbols are commonly used to define the stored faults status commands:
• #
Fault number (0 to 9). “0” is the first fault stored.
• hh
Hours in 24-hr. format.
• mm
Minutes.
• ss
Seconds.
• MM
Month.
• DD
Day.
• YY
Year.
Operational
Stored
Faults
Command:
Response:
MOD_xxx'cr'
DMD_xxx'cr''lf']
TX Operational Status (OK/FLT)
RX Operational Status (OK/FLT)
System
Stored
Faults
Command:
Response:
M&C_xxx'cr'
INT_xxx'cr'
BAT_xxx'cr'
+5_xxx'cr'
+12_xxx'cr'
PS1_xxx'cr'
PS2_xxx'cr'
COM_xxx'cr'
MVFY_xxx'cr'
DVFY_xxx'cr''lf']
Monitor & Control Module (OK/FLT)
Data Interface/Overhead Module (OK/FLT)
Battery/Clock (OK/FLT)
+5V Power Supply (OK/FLT)
+12V Power Supply (OK/FLT)
Power Supply #1 (OK/FLT)
Power Supply #2 (OK/FLT)
Modem Communications (OK/FLT)
Mod Config Verify (OK/FLT)
Demod Config Verify (OK/FLT)