beautypg.com

Comtech EF Data SMS-301 User Manual

Page 80

background image

Maintenance

SMS-301 Redundancy Switch

Rev. 3

5-2

Remove and replace U30 and/or U32 on printed circuit assembly as follows:

C AU TIO N

When replacing the 1:1 switch software, the previous switch configuration
and loaded modem configurations will be lost.

1. Disconnect power supply from the 1:1 switch.

2. Disconnect and remove 1:1 switch from equipment rack.

3. Remove top cover fasteners and cover.

4. Remove and replace U30 and/or U32 on printed circuit assembly, AS/5950. U30

and U32 are socketed devices.

5. Replace cover and fasteners.

6. Position and reconnect the 1:1 switch in rack.

7. Reconnect power supply to the 1:1 switch.

8. Enter desired 1:1 switch configuration.

9. Load all modems from Load/Verify menu or remote terminal.

10. Resume Auto mode as required.