SMS-301 Redundancy Switch

Operation

Rev. 3

3-23

3.5.1.8 Utility

System

Refer to Figure 3-11.

TIME: HH:MM:SS AM
DATE: MM/DD/YY

Time of day and date display/set function.

To change the time and/or date:

Note: Ensure 1:1 switch is in MANUAL mode.

Press [

←] or [→] to position the cursor over the parameter to

be changed. Press [

↑] or [↓] to change the parameter. Once the

parameters are set as desired, press [ENTER] to set the time
and date.

REMOTE BAUD RATE

The parity and baud rate settings of the 1:1 switch are
displayed.

To change the baud rate and/or parity, perform the following:

Note: Ensure 1:1 switch is in MANUAL mode.

The available baud rates are as follows: 150, 300, 600, 1200,
2400, 4800, 9600, or 19200 bps. Baud rates are set by pressing
[ENTER], and then [

↑] or [↓] to select the desired rate. Press

[ENTER] to accept the change, or [CLEAR] to abandon the
change.

The parity can be set to EVEN, ODD, or NONE, by pressing
[ENTER], [

→] to place the cursor on the parity setting, and

then [

↑] or [↓] to select the desired setting. Press [ENTER] to

accept the change, or [CLEAR] to abandon the change.

REMOTE ADDRESS

The current 1:1 switch address is displayed (1 to 255).

To change the remote address, press [ENTER], then [

←] or

[

→] to position the cursor over the parameter to be changed.

Press [

↑] or [↓] to change the parameter, then press [ENTER]

to accept the change, or [CLEAR] to abandon the change.

Note: A 0 address is reserved for global use only.

REMOTE TYPE

Displays the current remote type: EIA-232, EIA-485 (2-Wire),
or EIA-485 (4-Wire).

To change the remote type, press [ENTER], then any of the
arrow keys to select the desired remote type. Press [ENTER]
to accept the change, or [CLEAR] to abandon the change.

LAMP TEST ??
PRESS ENTER

Lamp test function. Press [ENTER] to turn all front panel LED
indicators ON for 3 seconds.