8 utility system – Comtech EF Data SMS-301 User Manual
Page 61

SMS-301 Redundancy Switch
Operation
Rev. 3
3-23
3.5.1.8 Utility
System
TIME: HH:MM:SS AM
DATE: MM/DD/YY
Time of day and date display/set function.
To change the time and/or date:
Note: Ensure 1:1 switch is in MANUAL mode.
Press [
←] or [→] to position the cursor over the parameter to
be changed. Press [
↑] or [↓] to change the parameter. Once the
parameters are set as desired, press [ENTER] to set the time
and date.
REMOTE BAUD RATE
The parity and baud rate settings of the 1:1 switch are
displayed.
To change the baud rate and/or parity, perform the following:
Note: Ensure 1:1 switch is in MANUAL mode.
The available baud rates are as follows: 150, 300, 600, 1200,
2400, 4800, 9600, or 19200 bps. Baud rates are set by pressing
[ENTER], and then [
↑] or [↓] to select the desired rate. Press
[ENTER] to accept the change, or [CLEAR] to abandon the
change.
The parity can be set to EVEN, ODD, or NONE, by pressing
[ENTER], [
→] to place the cursor on the parity setting, and
then [
↑] or [↓] to select the desired setting. Press [ENTER] to
accept the change, or [CLEAR] to abandon the change.
REMOTE ADDRESS
The current 1:1 switch address is displayed (1 to 255).
To change the remote address, press [ENTER], then [
←] or
[
→] to position the cursor over the parameter to be changed.
Press [
↑] or [↓] to change the parameter, then press [ENTER]
to accept the change, or [CLEAR] to abandon the change.
Note: A 0 address is reserved for global use only.
REMOTE TYPE
Displays the current remote type: EIA-232, EIA-485 (2-Wire),
or EIA-485 (4-Wire).
To change the remote type, press [ENTER], then any of the
arrow keys to select the desired remote type. Press [ENTER]
to accept the change, or [CLEAR] to abandon the change.
LAMP TEST ??
PRESS ENTER
Lamp test function. Press [ENTER] to turn all front panel LED
indicators ON for 3 seconds.