beautypg.com

2 configuration system menu – Comtech EF Data SMS-301 User Manual

Page 51

background image

SMS-301 Redundancy Switch

Operation

Rev. 3

3-13

3.5.1.2

Configuration System Menu

Refer to Figure 3-5 for the Configuration System.

SWITCH MODE

Programs the 1:1 switch to INDEPENDENT or DEPENDENT mode.

DEPENDENT— If a prime component (modulator or demodulator)
faults, the prime system will go off-line. The backup system
(modulator and demodulator) will come on-line.

INDEPENDENT— If a prime component (modulator or
demodulator) faults, the backup component (modulator or
demodulator) will come on-line.

Note: Ensure 1:1 switch is in MANUAL mode.

Upon entry, the current status of the 1:1 switch is displayed. Press
[ENTER], then use any of the arrow keys to select. Press [ENTER] to
execute the change, or [CLEAR] to abandon the change.

MODEM DELAY

Programs a switching delay of 0 to 127 seconds, in 0.5 second
increments.

Note: Ensure 1:1 switch is in DEPENDENT mode

Upon entry, the current status of the 1:1 switch is displayed. Press
[

←] or [→] to move the flashing cursor. Press [↑] or [↓] to increase

or decrease the numbers. Press [ENTER] to execute the change, or
[CLEAR] to abandon the change.

MODULATOR DELAY

Programs a switching delay of 0 to 127 seconds, in 0.5 second

increments.

Note: Ensure 1:1 switch is in INDEPENDENT mode

Upon entry, the current status of the 1:1 switch is displayed. Press
[

←] or [→] to move the flashing cursor. Press [↑] or [↓] to increase

or decrease the numbers. Press [ENTER] to execute the change, or
[CLEAR] to abandon the change.

DEMODULATOR
DELAY

Programs a switching delay of 0 to 127 seconds, in 0.5 second
increments.

Note: Ensure 1:1 switch is in INDEPENDENT mode

Upon entry, the current status of the 1:1 switch is displayed. Press
[

←] or [→] to move the flashing cursor. Press [↑] or [↓] to increase

or decrease the numbers. Press [ENTER] to execute the change, or
[CLEAR] to abandon the change.

MODULATORS

Programs the modulators to ACTIVE or INACTIVE.

Note: Ensure 1:1 switch is in MANUAL mode.

Upon entry, the current status of the 1:1 switch is displayed. Press
[ENTER], then use any of the arrow keys to select. Press [ENTER] to
execute the change, or [CLEAR] to abandon the change.

DEMODULATORS

Programs the demodulators to ACTIVE or INACTIVE.