Operation

SMS-301 Redundancy Switch

3-2

Rev. 3

3.2

Setup and Configuration

Table 3-1 details the default configuration parameters of the 1:1 switch. The 1:1 switch
is returned to this default configuration by performing a hard reset, or upon
failure/corruption of non-volatile memory.

Table 3-1. Default Configuration Parameters

Parameter

Condition

Operation Mode

Automatic

On-line Modem

A

On-line Mod

A

On-line Demod

A

Switch Mode

Independent

Modem Delay

0.0

Mod Delay

0.0

Demod Delay

0.0

Modulators

Active

Demodulators

Active

Time

12:00:00 AM

Date

7/04/76

Remote Baud Rate

9600 bit/s Even

Remote Address

10

Remote Type

EIA-485 (2-wire)

Display Contrast

Level 64

Automatic Verify

Disable

Modem A Address

1

Modem B Address

2

Modem Baud Rate

9600 bit/s

The following sections detail the minimum modifications necessary to set up a typical
1:1 redundant configuration. In the following setup descriptions, it is assumed Modem A
connections are to the prime modem. While proper switch operation does not require
Modem A to be the prime modem, it should be noted that upon loss of prime power to
the 1:1 switch, Modem A is the default signal pass through path.