Remote switch control (j1) (rs-301 option) – Comtech EF Data SMS-301 User Manual
Page 27

SMS-301 Redundancy Switch
Installation
Rev. 3
2–5
2.3.1
Remote Switch Control (J1) (RS-301 Option)
For applications using the Remote Switch (RS-301) option, the connector type is a
37-pin D subminiature. Refer to Table 2-3 for the 37-pin connector pin assignments.
Table 2-3. Switch Control Interface Signals
Pin No.
Name
Function
1
SCL
Serial Clock
20
SDA
Serial Data
2
Spare 11
No Connection
21
Spare 10
No Connection
3
Spare 9
No Connection
22
Spare 8
No Connection
4
Spare 7
No Connection
23
Spare 6
No Connection
5
Spare 5
No Connection
24
Spare 4
No Connection
6
Spare 3
No Connection
25
Spare 2
No Connection
7
Spare 1
No Connection
26
DMDONL
Demod Online
8
MODONL
Mod Online
27
/B_DF
Modem B Demod Fault
9
/A_DF
Modem A Demod Fault
28
/B_MF
Modem B Mod Fault
10
/A_MF
Modem A Mod Fault
29
ID_5
Interface Board ID
11
ID_4
Interface Board ID
30
ID_3
Interface Board ID
12
ID_2
Interface Board ID
31
ID_1
Interface Board ID
13
GND
Ground
32
GND
Ground
14
GND
Ground
33
GND
Ground
15
GND
Ground
34
-12V
-12VDC
16
-12V
-12VDC
35
+12V
+12VDC
17
+12V
+12VDC
36
+5V
+5VDC
18
+5V
+5VDC
37
+5V
+5VDC
19
+5V
+5VDC