Table 4-8, Table 4-9, Table 4-10 – Comtech EF Data SMS-301 User Manual
Page 74

Theory of Operation
SMS-301 Redundancy Switch
4-8
Rev. 3
Table 4-8. Tributary 7 Data (J7)
Pin No.
Name
Function
1
CTS422A7
EIA-422, Clear-to-Send A (-)
2,5,11
GND
Ground
3
TC422B-7
EIA-422, TX Clock B (+)
4
TD422A-7
EIA-422 TX Data A (-)
6
TD232-7
EIA-232 TX Data
9
CTS422B7
EIA-422 Clear-to-Send B (+)
10
TC422A-7
EIA-422 TX Clock A (-)
12
TD422B-7
EIA-422 TX Clock B (+)
13
CTS232-7
EIA-232 Clear-to-Send
14
TC232-7
EIA-232 TX Clock
Table 4-9. Tributary 8 Data (J8)
Pin No.
Name
Function
1
CTS422A8
EIA-422, Clear-to-Send A (-)
2,5,11
GND
Ground
3
TC422B-8
EIA-422, TX Clock B (+)
4
TD422A-8
EIA-422 TX Data A (-)
6
TD232-8
EIA-232 TX Data
9
CTS422B8
EIA-422 Clear-to-Send B (+)
10
TC422A-8
EIA-422 TX Clock A (-)
12
TD422B-8
EIA-422 TX Clock B (+)
13
CTS232-8
EIA-232 Clear-to-Send
14
TC232-8
EIA-232 TX Clock
Table 4-10. AUX Data (J9)
Pin No.
Name
Function
1
MCA
TX Aggregate Clock
2,5,11
GND
Ground
3
RT-B
EIA-422, RX Timing B (+)
4
RD-A
EIA-422, RX Data A (-)
6
RR-B
RX Ready B (+)
7
N/C
No Connection
8
MF
MOD Fault
9
MCB
TX Aggregate Data
10
RT-A
EIA-422, RX Timing A (-)
12
RD-B
EIA-422, RX Data B (+)
13
RR-A
RX Ready A (-)
14
N/C
No Connection
15