beautypg.com

5 monitor menu, Figure 3-8. monitor menu, Re fer to figure 3-8 – Comtech EF Data SMS-301 User Manual

Page 55

background image

SMS-301 Redundancy Switch

Operation

Rev. 3

3-17

S M S - 3 0 1

VER: X.X.X

F U N C T I O N S E L E C T

M O N I T O R

M O D M M X - O N L I N E

D M D D D Y - O N L I N E

MM = A and B,

Modulators Active.

DD = A and B,

Demodulators Active.

X = A or B, Modulator Online.

Y = A or B, Demodulator Online.

Status only.

A C C E S S T O

S U B M E N U

C O N D I T I O N A L O R

O P T I O N - D E P E N D E N T

P a r a m e t e r I n f o r m a t i o n

Key:

Figure 3-8. Monitor Menu

3.5.1.5 Monitor

Menu

Refer to Figure 3-8.

MOD MM X–ONLINE
DMD DD Y–ONLINE

(Status Only.)

Line 1 displays summary of active prime modems and online
backup modems.
Line 2 displays summary of active prime and online backup
demodulators.

Where:

MM = A and B, indicates modulators are active.
If not active, an “_” is displayed.

DD = A and B, indicates demodulators are active.
If not active, an “_” is displayed.

X = A or B, indicates modulator A or B online.

Y = A or B, indicates demodulators A or B online.