Status/fault (j14), If connections: transmit and receive, Ground – Comtech EF Data SMS-301 User Manual
Page 38: 8 status/fault (j14), 9 if connections: transmit and receive, 10 ground

Installation
SMS-301 Redundancy Switch
2–16
Rev. 3
2.3.8 Status/Fault
(J14)
Refer to Table 2-14 for Status/Faults (J14) pinout assignments.
Connector-Type:
15-Pin D Subminiature, female Form C contact
Rating 2A maximum @ 30 VDC, 0.6A @ 125 VAC
Table 2-14. Status/Faults (J14) Pinout Assignments
Pinout
Pin #
Name
Function
1
Spare COM
2
Spare NO
3
Spare NC
4
CEQ COM
5
CEQ NO
Common Equipment OK
6
CEQ NC
Common Equipment Faulted
7
MODONL COM
8
MODONL NO
Mod B On-line Status
9
MODONL NC
Mod A On-line Status
10
SW COM
11
SW NO
Switch OK
12
SW NC
Switch Faulted
13
DMDONL COM
14
DMDONL NO
Demod B On-line Status
15
DMDONL NC
Demod A On-line Status
2.3.9
IF Connections: Transmit and Receive
The data is provided in the following listing:
Connector type
BNC 75
Ω (50Ω Optional)
Return loss
≥ 18 dB from 50 to 180 MHz
2.3.10 Ground
A #10-32 stud is provided on the rear of the chassis for connecting a common chassis
ground between all of the equipment.