beautypg.com

Status/fault (j14), If connections: transmit and receive, Ground – Comtech EF Data SMS-301 User Manual

Page 38: 8 status/fault (j14), 9 if connections: transmit and receive, 10 ground

background image

Installation

SMS-301 Redundancy Switch

2–16

Rev. 3

2.3.8 Status/Fault

(J14)

Refer to Table 2-14 for Status/Faults (J14) pinout assignments.

Connector-Type:

15-Pin D Subminiature, female Form C contact
Rating 2A maximum @ 30 VDC, 0.6A @ 125 VAC

Table 2-14. Status/Faults (J14) Pinout Assignments

Pinout

Pin #

Name

Function

1

Spare COM

2

Spare NO

3

Spare NC

4

CEQ COM

5

CEQ NO

Common Equipment OK

6

CEQ NC

Common Equipment Faulted

7

MODONL COM

8

MODONL NO

Mod B On-line Status

9

MODONL NC

Mod A On-line Status

10

SW COM

11

SW NO

Switch OK

12

SW NC

Switch Faulted

13

DMDONL COM

14

DMDONL NO

Demod B On-line Status

15

DMDONL NC

Demod A On-line Status

2.3.9

IF Connections: Transmit and Receive

The data is provided in the following listing:

Connector type

BNC 75

Ω (50Ω Optional)

Return loss

≥ 18 dB from 50 to 180 MHz

2.3.10 Ground

A #10-32 stud is provided on the rear of the chassis for connecting a common chassis