SMS-301 Redundancy Switch
Operation
Rev. 3
3-7
3.5 Menu
System
To access and execute all functions, refer to Figure 3-3 through Figure 3-12. Use the
main menu in Figure 3-3 as a quick reference for accessing the 1:1 switch functions. For
further configuration details, refer to Section 3.2.
When the 1:1 switch power is turned ON, the base level of the menu system displays the
sign-on message:
•
Line 1 of the sign-on message is the 1:1 switch model number and type.
•
Line 2 is the version number of the firmware.
The main level of the menu system is Function Select. To access this level from the
sign-on message, press the [
←] or [→] keys. From the Function Select menu, select one
of the functional categories:
•
Configuration
•
Monitor
•
Faults/Alarms
•
Stored Faults/Alarms
•
Utility
Press [
←] or [→] to move from one selection to another. When line 2 displays the
desired function, select that level by pressing [ENTER]. After entering the appropriate
functional level, press [
←] or [→] to move to the desired function.
To view or change the configuration of the 1:1 switch, enter the Configuration level from
the Function Select menu. Once in the Configuration menu, press [
←] or [→] to scroll
through the Configuration menu selection.
Press [ENTER] to select the desired Configuration menu option. To view the options for
the selected configuration parameters, press [
←] or [→]. To change a configuration
parameter, press [ENTER] to begin the change process.