SMS-301 Redundancy Switch

Operation

Rev. 3

3-5

3.2.2.3 Operation

Mode

Two modes of operation are available for the 1:1 switch:

AUTOMATIC

If the AUTOMATIC mode is selected, the 1:1 switch algorithm
will perform backup operations as defined in the Configuration
menus.

MANUAL

When the MANUAL mode is selected, the system provides a
dedicated menu through which the operator may unconditionally
assign backup RX and TX functions to replace the prime
modem.

Note: The 1:1 switch shall be in AUTOMATIC mode to automatically replace the
faulted prime.

The manual configuration may be used when Modem A parameters are to be different
than Modem B. The 1:1 switch is then used as a master switch. Turn automatic verify
off. (The automatic verify is located under the Utility Modem Control menu.)

3.3 Faults

Alerts to modem or 1:1 switch faults are provided in several ways:

Indicators on the 1:1 switch control panel, with specific information available in
the Faults/Alarms menu.

On demand via the 1:1 switch remote port. Specifics for 1:1 switch and modem
faults are available.

Analog status/fault indication signals on the rear of the 1:1 switch (J14).

Note: Refer to Chapter 5 for troubleshooting switch faults, or the respective modem
manual for modem faults.