beautypg.com

Specifications, 3 specifications – Comtech EF Data SMS-301 User Manual

Page 20

background image

Introduction

SMS-301 Redundancy Switch

1–6

Rev. 3

1.3 Specifications

Refer to Table 1-3 for the 1:1 switch specifications.

Table 1-3. 1:1 Switch Specifications

Data Interface Switch:

Modem A, I/O
Modem B, I/O
Common, I/O

Connector type:

25-pin D-sub,
37-pin D-sub
50-pin D-sub
100-pin D-sub

Control Bus Extender Card

Connector Type:

37-pin D-sub (Remote Switch)

IF Uplink Switch:

Connector type:

BNC

Impedance: 75

Ω (50Ω optional)

Return loss:

≥ 18 dB

Switched input to output loss: < 1.5 dB
Frequency response: 50 to 180 MHz
IF input to input isolation: > 60 dB

IF Downlink Splitter:

Connector type:

BNC

Impedance: 75

Ω (50Ω optional)

Return loss:

≥ 18 dB

Splitter loss, input to outputs: < 4.0 dB
Output balance:

± 0.5 dB

Frequency response: 50 to 180 MHz

Local User Interface

Front Panel:

Keypad: 6 button (enter, clear, left, right, up, down arrows)

Display: backlit LCD, 2 lines by 16 characters

Front Panel Status LEDs

Operational mode:

Manual (Yellow)

Automatic (Green)

Switch faults:

TX (Red)

RX (Red)

System (Red)

Stored (Yellow)

On-line Status:

Modulator A (Green)

Modulator B (Green)

Demodulator A (Green)

Demodulator B (Green)

On-line/Fault Status
Modulator On-line
Demodulator On-line
Switch Fault
Controller Fault
Spare

Rear panel, 15-pin D-sub female
Form C relay
Form C relay
Form C relay
Form C relay
Form C relay

Remote Control

Interface type:

EIA-485/EIA-232 (local selectable)

Connector:

9-pin D-sub

Protocol:

Addressable (see remote control protocol)