beautypg.com

System commands/responses, A.5 system commands/responses – Comtech EF Data SMS-301 User Manual

Page 89

background image

SMS-301 Redundancy Switch

Remote Control Operation

Rev. 3

A-7

A.5 System

Commands/Responses

Time Of
Day

Command:
Response:

Status:
Response:

>add/TIME_hh:mmxx'cr''lf']

>add/TIME_hh:mmxx'cr''lf']

Where:

hh = 1 to 12 (hours).
mm = 00 to 59 (minutes).
xx = AM or PM.

Date

Command:
Response:

Status:
Response:

>add/DATE_mm/dd/yy'cr''lf']

>add/DATE_mm/dd/yy'cr''lf']

Where:

mm = 1 to 12 (month).
dd = 1 to 31 (day).
yy = 00 to 99 (year).

Remote
Operation

Command:
Response:

>add/REM_'cr''lf']

Configures the SMS301 for remote operation.

The SMS301 will respond to any status request at any time.
However, the SMS301 must be in 'Remote Mode' to change
configuration parameters remotely.

Clear
Stored
Faults

Command:
Response:

>add/CLSF_'cr''lf']

This command is used to clear all stored faults logged by the
SMS301.

Power
Supply
Monitor

Command:
Response:

Status:
Response:

>add/PS_xxx'cr''lf']

>add/PS_xxx'cr''lf']

Where: xxx = 1 (monitor power supply #1), 2 (monitor power
supply #2), 1&2 (monitor power supply #1 & #2).

Save Switch
Config.

Command:
Response:

>add/SMC_n'cr''lf']

Where: n = 1, 2, 3, 4, or 5 (stored configuration number).

This command saves the current switch configuration for
recall at a later time using the "RMC_" command. Up to five
different switch configurations can be saved.

Recall
Switch
Config.

Command:
Response:

>add/RMC_n'cr''lf']

Where: n = 1, 2, 3, 4, or 5 (stored configuration number).

This command causes the switch to be reprogrammed with
configuration parameters previously saved using the "SMC_"
command. One of five saved configurations can be specified.